RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 10604

Siemens alarm 10604: Channel %1 block %2 thread lead increase too high

SINUMERIK channel alarm · Siemens 840D/810D powerline

What it means

In a thread block with linearly increasing lead, the programmed lead gain exceeds what the axis dynamics permit. The resulting acceleration demand on path axes or spindle would exceed machine limits. The lead increase must be reduced or spread over more revolutions.

Likely causes

  • Lead-increase value too large per spindle revolution
  • Thread ramp compressed into too few revolutions
  • High spindle speed combined with large lead change

Need the part urgently?

Send us alarm 10604 with your machine details — typical RFQ turnaround is 24–48h.