RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 10605

Siemens alarm 10605: Channel %1 block %2 thread lead decrease too high

SINUMERIK channel alarm · Siemens 840D/810D powerline

What it means

The programmed lead reduction in a tapering thread block is greater than permissible. A steeply decreasing lead would drive the effective lead negative before the block ends, which has no physical meaning. The decrease rate must keep the instantaneous lead positive throughout the block.

Likely causes

  • Lead-decrease value too large per revolution
  • Lead ramp ending near zero lead within one block
  • Incorrect sign or unit when programming the lead change

Need the part urgently?

Send us alarm 10605 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog