Siemens alarm 10620: [Channel 1: ] Block %3 axis %2 at software limit switch %4

SINUMERIK 808D alarm · Siemens 808D

What it means

During traversing the NCK determined that a software limit would be exceeded, typically because a handwheel overlay, work offset or coordinate transformation shifted the effective traversing range after block preparation. The block stops at its end and NC start remains inhibited for the channel until RESET.

Likely causes

  • Work offset (G54 etc.) or preset moves axis outside limits
  • Handwheel/DRF overlay active during program run
  • Incorrect MD36100/36110 software limit values after mechanical change

Need the part urgently?

Send us alarm 10620 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog