RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 10750

Siemens alarm 10750: Channel %1 block %2 tool radius compensation activated without tool number

SINUMERIK channel alarm · Siemens 840D/810D powerline

What it means

G41/G42 cutter radius compensation was switched on although no valid tool with usable radius data is selected. Without current T/D offset geometry the controller cannot compute the offset contour, so activation is refused. Select a tool with radius data before enabling compensation.

Likely causes

  • G41/G42 activated before any T/D selection
  • Selected D number contains no radius data (tool type without radius)
  • Tool offset table entry cleared or not loaded

Need the part urgently?

Send us alarm 10750 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog