Siemens alarm 10754: Channel %1 block %2 deselection of the tool radius compensation only possible in linear block

SINUMERIK channel alarm · Siemens 840D/810D powerline

What it means

Compensation must be cancelled with G40 in a straight-line block so the tool returns to the programmed contour along a defined path. Deselection on an arc block leaves the exit position ambiguous and is therefore blocked. Add a linear retract block before G40.

Likely causes

  • G40 placed in an arc/curved retract block
  • Macro cancelling CRC mid-contour
  • Program end reached with CRC still active on a curved path

Need the part urgently?

Send us alarm 10754 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog