Siemens alarm 10757: Channel %1 block %2 changing the compensation plane while tool radius compensation is active not possible

SINUMERIK channel alarm · Siemens 840D/810D powerline

What it means

The compensation plane selection (G17/G18/G19) may not change while radius compensation is active. The offset vector is referenced to the current plane, and switching planes mid-compensation corrupts the geometry calculation. Cancel with G40, switch plane, then re-enable compensation.

Likely causes

  • Plane-change block inserted between G41 and G40
  • Cycle switching planes internally while main-program CRC is still modal
  • Copy-pasted program sections leaving CRC modal across plane changes

Need the part urgently?

Send us alarm 10757 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog