Siemens alarm 10763: Channel %1 block %2 path component of the block in the compensation plane becomes zero
SINUMERIK channel alarm · Siemens 840D/810D powerline
What it means
While radius compensation is active, a block was programmed that moves only perpendicular to the compensation plane, leaving zero projected path length in that plane. The compensated side of such a block is undefined. Move the third-axis motion outside the compensated section or add an in-plane component.
Likely causes
- Pure Z plunge block inside an XY compensated contour (G17)
- Retract block moving only along the tool axis while CRC is active
- Drilling-style move embedded in a milling contour program
Need the part urgently?