Siemens alarm 10764: Channel %1 block %2 discontinuous path with active tool radius compensation
SINUMERIK channel alarm · Siemens 840D/810D powerline
What it means
With radius compensation active the contour must be continuous, but a positional gap was detected between consecutive blocks. Compensating across a jump would offset the wrong edge, so the alarm is raised. Ensure every contour element connects to the next endpoint without interruption.
Likely causes
- Missing intermediate block after CAD/CAM postprocessing
- Chamfer/rounding instruction consuming an entire block and leaving a gap
- Coordinate typo creating a jump between contour elements
Need the part urgently?
Send us alarm 10764 with your machine details — typical RFQ turnaround is 24–48h.