Siemens alarm 10800: Channel %1 block %3 axis %2 is not a geometry axis

SINUMERIK channel alarm · Siemens 840D/810D powerline

What it means

A block addressed a channel axis that is not declared as a geometry axis, although the used function requires one. Geometry axes are the principal interpolation axes configured per channel in machine data. Either the wrong axis name was programmed or the channel axis assignment no longer matches the program.

Likely causes

  • Axis identifier configured as special/channel axis only
  • Program written for another channel's axis layout
  • Geometry axis assignment changed in machine data after program was written

Need the part urgently?

Send us alarm 10800 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog