Siemens alarm 10882: Channel %1 block %2 activation of chamfers or radii (non-modal) without traversing movement in the block
SINUMERIK channel alarm · Siemens 840D/810D powerline
What it means
A non-modal chamfer (CHF/CHR) or corner radius (RND) was programmed in a block that contains no axis movement. Corner elements modify the transition between two traversing blocks; without motion there is no corner to break. Attach the keyword to a block with actual path motion.
Likely causes
- CHF=/RND= written on a block containing only F, M or T words
- Template line left empty of coordinates
- Macro generating modifier lines without movement
Need the part urgently?