Siemens alarm 10933: Channel %1 block %2 contour program does not contain enough contour blocks

SINUMERIK channel alarm · Siemens 840D/810D powerline

What it means

A stock-removal contour description was evaluated but contains fewer traversing contour elements than needed to define a machinable profile boundary. At minimum two meaningful contour blocks are required. Enrich or correct the contour subprogram.

Likely causes

  • Contour subprogram reduced to a single positioning block
  • Blocks commented out or skipped by jumps
  • Wrong file selected as the contour description