Siemens alarm 132*: Closed-loop system hardware axis

SINUMERIK 840C legacy alarm · Siemens 840C

What it means

The measuring-circuit difference signals are out of phase, have an earth fault or are missing completely, so position feedback hardware has failed. Check connector seating, use the measuring-circuit short-circuit connector to test the group, inspect difference signals and MD 200*/384* settings; replace encoder if needed. Cleared only by POWER ON.

Likely causes

  • Encoder/scale cable disconnected or damaged
  • Earth fault in measuring-circuit lines
  • Failed pulse encoder or EXE evaluation electronics

Triage note: * suffix = axis index; cleared only by POWER ON

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • pulse encoder / measuring system per axis spare list

    encoder · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 132* with your machine details — typical RFQ turnaround is 24–48h.