RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 14011

Siemens alarm 14011: Channel %1 block %2 program %3 not found

SINUMERIK NCK general alarm · Siemens 840D/810D powerline

What it means

A program call refers to a program that does not exist in the NCK program memory. Per the Diagnostics Guide this typically occurs when the PI service FB-4 (program selection via PLC) is applied to a non-existent program, or a subprogram call, SETINT statement or PROC statement names a misspelled identifier. The block pointer stops at the offending block.

Likely causes

  • Typing error in the program name given in parameter %3
  • Program deleted, renamed or never transferred to the NCK
  • PLC (FB-4) selecting a program path/name that does not exist
  • Wrong directory (e.g. cycle not in _N_CST_DIR/_N_CMA_DIR)

Triage note: Check spelling and location of the called program; verify PLC-selected program names after archives are reloaded.

Need the part urgently?

Send us alarm 14011 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog