Siemens alarm 15122: Power ON after power failure: %1 data were restored, of which %2 machine data, %3 errors
SINUMERIK NCK general alarm · Siemens 840D/810D powerline
What it means
Notification alarm issued after a power failure or uncontrolled power-off: the NCK restored persistent data during the subsequent power-up, reporting how many restoration steps were performed, how many of them were machine data, and how many errors occurred. As long as the error count (%3) is zero there is no negative effect. A non-zero error count means some persistent data could not be recovered reliably.
Likely causes
- Mains dropout or emergency-off during writing of persistent data
- Battery-backed memory write interrupted (weak battery plus power loss)
- Excessive write activity to the persistent file system (check MD18232 log settings)
- File system inconsistency after repeated uncontrolled shutdowns
Triage note: If %3 > 0, compare/checksum the restored data and plan a series commissioning restore from archive; investigate why the power failure happened mid-write.