Siemens alarm 20001: [Channel %1: ] Axis %2 no cam signal present
SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline
What it means
Reference point approach was started, but the NCK never received a signal change from the reference cam input. Without a cam edge the following zero-mark evaluation cannot begin, so the referencing run is terminated.
Likely causes
- reference cam switch defective or mechanically out of adjustment
- open circuit in the cam signal line or connector
- PLC program does not pass the cam signal to the NCK interface
- input byte/bit assignment for the cam signal incorrect in machine data
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
proximity switch / sensor cable per machine tool builder
cable · Check if others ruled out
Need the part urgently?
Send us alarm 20001 with your machine details — typical RFQ turnaround is 24–48h.