What it means

The connected incremental measuring system does not supply any reference marks at all, so referencing by cam-plus-zero-mark is impossible. This typically appears when the encoder type does not match the configuration or the mark track is dead.

Likely causes

  • absolute encoder operated/configured without reference-mark evaluation while REFP_MODE expects marks
  • zero-mark track of the encoder defective
  • wrong encoder type entered in MD 30240 ENC_TYPE after encoder exchange
  • signal evaluation electronics faulty

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 20004 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog