Siemens alarm 2003*: Zero speed monitoring

SINUMERIK 840C legacy alarm · Siemens 840C

What it means

Spindle-specific standstill supervision: when positioning/clamped, the following error was not eliminated within the 'Cutoff delay servo enable' time, or the clamped spindle was pushed outside the 'Zero speed monitoring' window. Indicates drive/actuator/tacho faults, mechanical displacement or commissioning errors such as wrong position-control sense.

Likely causes

  • Fault in activating device, tacho or spindle motor
  • Clamped spindle mechanically displaced
  • Wrong setpoint-output assignment or control direction at start-up
  • 'Zero speed monitoring' MD smaller than 'Exact stop limit coarse'

Triage note: * suffix = spindle index