Siemens alarm 2110: NCK temperature alarm

SINUMERIK NCK general alarm · Siemens 840D/810D powerline

What it means

The temperature sensor on the NCU has reached its response threshold, indicating excessive temperature inside the NCU box or cabinet. Machining is not interrupted, but continued operation at high temperature accelerates component ageing. The alarm clears automatically once the sensor temperature drops again.

Likely causes

  • Blocked or failed NCU box fan(s)
  • Cabinet filter mats clogged or enclosure fans defective
  • Ambient temperature above specification (typically >40 °C)
  • NCU mounted directly above heat sources such as drives or transformers

Triage note: Check airflow through the NCU box and cabinet before replacing anything; clean filters regularly.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 2110 with your machine details — typical RFQ turnaround is 24–48h.