RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 2130

Siemens alarm 2130: 5V/24V encoder or 15V D/A converter undervoltage

SINUMERIK 828D alarm · Siemens 828D

What it means

The NCK detected a supply failure on the encoder voltage rails (5 V/24 V) or on the +/-15 V D/A-converter supply. Because a shorted encoder cable can drag these rails down, the reaction includes follow-up mode and all axes of the channel must be re-referenced afterwards.

Likely causes

  • Short circuit in encoder signal/supply cable
  • Defective encoder drawing excess current
  • Failure of the internal supply feeding encoders/D/A converter

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • encoder feedback cable / encoder per machine spare list

    encoder · Check if others ruled out