RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 2140

Siemens alarm 2140: The actual service switch position forces the SRAM to be cleared at the next Power On (general reset active)

SINUMERIK 808D alarm · Siemens 808D

What it means

The initialization (service) switch on the PPU is set to overall reset, so the complete NC data memory will be wiped at the next power-up. The alarm warns that all machine data will be lost unless the switch is returned to normal operation before restarting.

Likely causes

  • Service/init switch left in general-reset position after maintenance or data recovery
  • Switch mechanically loose or faulty

Need the part urgently?

Send us alarm 2140 with your machine details — typical RFQ turnaround is 24–48h.