RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 21612

Siemens alarm 21612: Channel %1 axis %2 VDI signal 'Servo enable' reset during motion

SINUMERIK axis alarm (hardware-triggered) · Siemens 840D/810D powerline

What it means

Servo/drive-enable signal dropped while the axis or a geometry-group axis was moving; position loop opened under motion.

Likely causes

  • bad connection at terminal T.663 (pulse enable) on 611D control card - most common
  • failed internal relay controlled by T.663 on the 611D card
  • device-bus (X351) ribbon cable defect
  • PLC enable chain drop-out (DBX93.7 / DBX2.1) from e-stop circuit, door interlock or contactor
  • drive-side fault collapsing 'Drive Ready' (DBX93.5)

Triage note: Often accompanied by 25201; monitor DBX93.7 during motion to separate PLC-side vs drive-side enable loss.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • 6SN1118-…

    SIMODRIVE 611D control board (T663 relay) · Primary suspect

    Request a quote →
  • 6FX2003-… / X351 ribbon 34-pin

    device/equipment bus cable · Common cause

    Request a quote →
  • enable-chain relays/contactors (per machine builder schematic)

    PLC enable hardware · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 21612 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog