Siemens alarm 21612: Channel %1 axis %2 VDI signal 'Servo enable' reset during motion
SINUMERIK axis alarm (hardware-triggered) · Siemens 840D/810D powerline
What it means
Servo/drive-enable signal dropped while the axis or a geometry-group axis was moving; position loop opened under motion.
Likely causes
- bad connection at terminal T.663 (pulse enable) on 611D control card - most common
- failed internal relay controlled by T.663 on the 611D card
- device-bus (X351) ribbon cable defect
- PLC enable chain drop-out (DBX93.7 / DBX2.1) from e-stop circuit, door interlock or contactor
- drive-side fault collapsing 'Drive Ready' (DBX93.5)
Triage note: Often accompanied by 25201; monitor DBX93.7 during motion to separate PLC-side vs drive-side enable loss.