Siemens alarm 21614: [Channel %1: ] Axis %2 hardware limit switch %3
SINUMERIK 828D alarm · Siemens 828D
What it means
A hardware limit-switch signal (+/-) arrived at PLC interface inputs DB380x DBX1000.0/.1 and NC start is disabled for the axis. On referenced axes the software limits should respond first; if they do not, limit machine data (MD36100/36110/36120/36130) or switch positions are wrong.
Likely causes
- Axis jogged into physical limit switch before homing
- Software limit machine data misconfigured
- Defective limit switch or wiring giving permanent signal
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
axis limit switch per machine electrical drawings
limit switch · Check if others ruled out
Need the part urgently?
Send us alarm 21614 with your machine details — typical RFQ turnaround is 24–48h.