RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 21614

Siemens alarm 21614: [Channel %1: ] Axis %2 hardware limit switch %3

SINUMERIK 828D alarm · Siemens 828D

What it means

A hardware limit-switch signal (+/-) arrived at PLC interface inputs DB380x DBX1000.0/.1 and NC start is disabled for the axis. On referenced axes the software limits should respond first; if they do not, limit machine data (MD36100/36110/36120/36130) or switch positions are wrong.

Likely causes

  • Axis jogged into physical limit switch before homing
  • Software limit machine data misconfigured
  • Defective limit switch or wiring giving permanent signal

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • axis limit switch per machine electrical drawings

    limit switch · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 21614 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog