Siemens alarm 22020: [Channel %1: ] Block %3 spindle %2 gear step change position not reached

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

While executing a gear change the spindle did not reach the required changeover speed/position window within the monitored time. The gearbox can only shift when the drive holds the spindle inside the narrow change-speed band.

Likely causes

  • drive unable to hold the change speed (torque limit, unstable speed loop)
  • friction or damage in the gearbox increasing the effort needed to turn the input shaft
  • change speed window or monitoring times set incorrectly
  • erratic encoder feedback making speed control oscillate