Home / Alarm Library / Siemens / 22064

Siemens alarm 22064: [Channel %1: ] Axis %2 reference point approach: zero marker search velocity (MD) is too high

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

The zero-marker search velocity in the referencing machine data is above what the axis may be commanded, for instance beyond the encoder frequency limit or the maximum axis velocity. Referencing is blocked until the value is corrected.

Likely causes

  • MD 34020 set higher than MD 32000 MAX_AX_VELO or encoder limit frequency
  • unit confusion (m/min vs mm/min, deg/min) after parameter edit
  • copied machine data from another axis with different dynamics

Need the part urgently?

Send us alarm 22064 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog