Siemens alarm 25001: Axis %1 hardware fault of passive encoder
SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline
What it means
The second (passive) measuring system of the axis reports a hardware fault, i.e. its signals are interrupted, implausible or absent. The passive encoder normally serves as monitoring/back-up system, so its failure degrades redundancy even if the axis still moves on the active encoder.
Likely causes
- direct measuring system (linear scale) defective or heavily contaminated
- broken encoder cable, loose connector or damaged coupling
- screening/earth bond interrupted causing signal corruption
- evaluation electronics in the drive measuring circuit faulty
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
linear/direct measuring system (per machine spec)
encoder · Common cause
- Request a quote →
6FX5002 series encoder signal cable
cable · Common cause
Need the part urgently?
Send us alarm 25001 with your machine details — typical RFQ turnaround is 24–48h.