Siemens alarm 25021: Axis %1 zero mark monitoring of passive encoder
SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline
What it means
Zero-mark monitoring of the passive measuring system responded: the reference mark relationship of the second encoder became implausible between sampling instants. The control cross-checks both encoders; a mismatch indicates signal problems or mechanical slip of the second system.
Likely causes
- intermittent zero-mark pulses from the second encoder
- slipping or loose coupling of the direct measuring system
- electrical noise from damaged screening
- encoder electronics beginning to fail
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
linear/direct measuring system (per machine spec)
encoder · Common cause
- Request a quote →
6FX5002 series encoder signal cable
cable · Common cause
Need the part urgently?
Send us alarm 25021 with your machine details — typical RFQ turnaround is 24–48h.