RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 25021

Siemens alarm 25021: Axis %1 zero mark monitoring of passive encoder

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

Zero-mark monitoring of the passive measuring system responded: the reference mark relationship of the second encoder became implausible between sampling instants. The control cross-checks both encoders; a mismatch indicates signal problems or mechanical slip of the second system.

Likely causes

  • intermittent zero-mark pulses from the second encoder
  • slipping or loose coupling of the direct measuring system
  • electrical noise from damaged screening
  • encoder electronics beginning to fail

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 25021 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog