RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 25050

Siemens alarm 25050: Axis %1 position monitoring / contour deviation too large

SINUMERIK axis monitoring alarm (hardware-consequential) · Siemens 840D/810D powerline

What it means

Actual position deviated from commanded contour beyond MD36400 - axis lagged or fought the command.

Likely causes

  • mechanical binding (ways, gib, ballscrew nut)
  • failed coupling or ballscrew bearing
  • vertical-axis counterbalance failure
  • failing drive delivering marginal torque (I2t reduction active)
  • encoder scale damage giving false actual position

Triage note: Check preceding alarms in history: I2t/temperature alarms immediately before 25050 shift suspicion from mechanics to the drive.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 25050 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog