Siemens alarm 25070: Axis %1 drift value too large

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

The drift observed between position setpoint and actual value at standstill exceeded the value that drift compensation may apply. Persistent drift usually reflects converter/encoder offset problems rather than pure parameter issues, since compensation is meant to trim only small offsets.

Likely causes

  • analog offset drift in the drive electronics (typical on aged 611D control boards)
  • encoder zero-position offset or damaged signal conditioning
  • temperature-dependent drift of measuring electronics
  • drift compensation limits (DRIFT machine data group) set unrealistically tight

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 25070 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog