Siemens alarm 25100: Axis %1 measuring system switchover not possible
SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline
What it means
A requested changeover between the axis measuring systems (e.g. motor encoder to direct scale) was rejected because the target system is unavailable, not synchronized, or the current state does not allow switching. Redundancy or accuracy changeover therefore did not happen.
Likely causes
- target encoder not connected/configured (MD 30240[n] = 0) or defective
- target measuring system not referenced/absolute position invalid
- switchover attempted during motion under disallowed conditions
- encoder changeover machine data inconsistent
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
linear/direct measuring system (per machine spec)
encoder · Check if others ruled out
Need the part urgently?
Send us alarm 25100 with your machine details — typical RFQ turnaround is 24–48h.