Siemens alarm 25105: Axis %1 measuring systems differ considerably
SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline
What it means
Active and passive measuring systems report positions deviating more than the tolerance (MD 36500 ENC_DIFF_TOL). Since both systems measure the same axis motion, a large divergence reveals mechanical or data problems rather than random noise.
Likely causes
- loose or slipping coupling of the direct measuring system
- ball screw pitch error/spindle stretch not compensated relative to the scale
- wrong scale offset or grid distance data after encoder exchange
- one of the two encoders delivering corrupted counts
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
linear/direct measuring system mounting/coupling per machine builder
encoder · Check if others ruled out