RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 25200

Siemens alarm 25200: Axis %1 requested set of parameters invalid

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

A request to activate another parameter set of the axis/drive (commonly tied to gear stage changes) referred to a set that does not exist or is not loaded completely. The switch is refused to prevent running with undefined dynamic data.

Likely causes

  • target parameter set number never created or deleted
  • PLC requests a set number outside the configured range
  • set data incomplete after archive restore or drive firmware update
  • request issued while the previous set change was still running

Need the part urgently?

Send us alarm 25200 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog