Siemens alarm 25201: Axis %1 drive %2 fault (ZK1 class 1 serious drive fault)

SINUMERIK 840D sl / 828D drive umbrella alarm (PROFIdrive) · Siemens 828D

What it means

Drive signalled serious status-class fault; root cause must be read from accompanying drive alarms (300500/300502-300505/300508/300515/300614 on PL) or SINAMICS F-codes / 380500 fault value (on sl/828D). Persistent after 25202 'waiting for drive' times out.

Likely causes

  • any underlying SINAMICS/611D hardware fault (overcurrent, I2t, encoder, DRIVE-CLiQ)
  • PROFIBUS/PROFINET drive communication interruption (loose connector, shield break)
  • cycle-time overrun on drive bus
  • drive electronics supply collapse

Triage note: On 840D sl/828D open Diagnosis > Alarms > drive fault buffer (r0947/r0949 equivalent) to get the exact SINAMICS fault before ordering parts.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • per underlying fault code

    read subordinate drive alarm / 380500 fault value first · Primary suspect

    Request a quote →
  • 6XV1830-… / 6SL3066-0BA00-…

    PROFIBUS / DRIVE-CLiQ cable · Common cause

    Request a quote →
  • NCU 71x.x (6FC5373-…) or PPU (6FC5370-…)

    NCU/CCU or PPU (only if bus master port failed) · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 25201 with your machine details — typical RFQ turnaround is 24–48h.