Siemens alarm 26002: Axis %1 encoder %2 parameterization error: number of encoder marks

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

The number of encoder lines/increments stored for this encoder is invalid or incompatible with the motor/drive identification. Correct conversion between motor revolutions and axis motion is impossible with wrong mark counts, so commissioning blocks the axis.

Likely causes

  • encoder line count typed wrongly after encoder exchange
  • motor/encoder order data (MLFB) not matching loaded drive dataset
  • value zero or negative entered
  • third-party encoder integrated without adapting the resolution data

Triage note: Verify against encoder nameplate/ordering data before changing values.