Siemens alarm 26003: Axis %1 parameterization error: lead screw pitch

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

The lead screw pitch machine data needed to convert motor revolutions into linear axis travel are missing or invalid (e.g. zero). The axis configuration is incomplete and the axis cannot be activated.

Likely causes

  • lead screw pitch (MD 31030) not entered or zero
  • pitch entered with wrong sign/unit after mechanics change
  • rack-and-pinion or other transmission configured with inappropriate pitch data

Need the part urgently?

Send us alarm 26003 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog