Siemens alarm 26020: Axis %1 encoder %2 hardware fault %3 during encoder initialization

SINUMERIK axis alarm (encoder hardware, 611D) · SIMODRIVE 611D/611U

What it means

Initialization of the absolute encoder failed; fine coding identifies interface problem (e.g. SSI level on data line, no encoder connected, incorrect cable, encoder faulty - bit 15).

Likely causes

  • encoder electronic failure (bit 15)
  • incorrect encoder cable / SSI level detected on EnDat data line (bit 11)
  • control board not supporting the encoder interface (EnDat/SSI)

Triage note: Evaluate error fine coding (%3) against absolute-encoder interface diagnostics table.