RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 26030

Siemens alarm 26030: Axis %1 encoder %2 absolute position lost

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

The absolute encoder's stored absolute position is no longer valid: the value could not be read plausibly at initialization or the permitted multi-turn range was violated. Position control requiring an absolute reference is blocked until the encoder is re-initialized/referenced.

Likely causes

  • serial communication error during encoder initialization (cabling, connectors)
  • encoder moved while control off beyond the permitted number of turns
  • internal encoder memory/electronics fault
  • absolute function machine data (MD 34200/34210) inconsistent after encoder swap

Triage note: After eliminating the cause, re-establish the absolute reference (re-referencing or absolute initialization) before production.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 26030 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog