Siemens alarm 26050: Axis %1 parameter set change from %2 to %3 not possible

SINUMERIK axis/spindle alarm · Siemens 840D/810D powerline

What it means

Switching the axis/drive parameter set (often linked to gear stages) from the current set to the requested one was refused. Both sets and the machine state must permit the change; otherwise the old set remains active.

Likely causes

  • target parameter set missing or identical to current set
  • change requested during motion or while another changeover is running
  • drive faulted or not enabled, refusing the switchover
  • PLC sequencing requests sets faster than the drive can apply them