What it means

An EMERGENCY STOP request has been applied to the NCK/PLC interface (DB10 DBX56.1 on 840D/810D). All axis motions and spindle operation are cancelled, the drive enables drop, and the channel goes to 'not ready'. The alarm remains until the e-stop chain is healthy again and the PLC acknowledges removal of the request.

Likely causes

  • E-stop pushbutton pressed, wired loose or defective
  • Safety guard/door interlock open or faulty switch
  • Broken conductor or missing 24 V anywhere in the hardwired safety chain
  • Safety relay/contactor failure, or PLC user program issuing e-stop

Triage note: Trace the open contact in the safety chain (door switches, e-stop buttons, relays); never bridge safety circuits.