Siemens alarm 300007: Axis %1 drive %2 not present or inactive

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

The axis machine data point to a drive logic number that does not exist in the active drive configuration: MD 30110 CTRLOUT_MODULE_NR / MD 30220 ENC_MODULE_NR reference a module not listed in MD 13010 DRIVE_LOGIC_NR. Typically appears after exchanging or removing a drive module, after an unpowered boot of one module, or when the drive configuration and axis assignment have drifted apart.

Likely causes

  • drive module missing, unpowered or failed at system boot
  • axis MDs (30110/30220) not matching the configured drive bus topology (MD 13010)
  • drive configuration edited without re-commissioning/re-booting the drives
  • control board not reporting on the drive bus

Triage note: First re-check drive configuration (Machine data -> drive summary) before touching hardware; most cases are configuration/power-up sequencing.