Siemens alarm 300100: Axis %1 drive %2 drive power failure

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

One or more 611D drives lost their power supply (DC link or electronics supply) during operation; the NC detected drives dropping off-line due to loss of power.

Likely causes

  • mains/line supply dip or phase loss feeding the infeed module
  • infeed module (I/R) tripped or failed internally
  • short circuit on the 600 V DC link bus (often a failed power module)
  • loose DC-link bus bars or burnt pre-charge contacts

Triage note: If NO LED lights on the infeed diagnostic panel although mains is present, suspect a short on the 600 V bus: loosen DC-link links module-by-module starting from the last (right-hand) module; the module whose removal clears the short is usually the failed power module.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • 6SN1145-… (I/R regulated infeed)

    SIMODRIVE 611 infeed/regenerative feed module · Primary suspect

    Request a quote →
  • 6SN1146-… (UE unregulated infeed)

    SIMODRIVE 611 infeed module · Common cause

    Request a quote →
  • 6SN1123-…

    SIMODRIVE 611 power module (if it shorts the DC bus) · Common cause

    Request a quote →