Siemens alarm 300500: Axis %1 drive %2 system error, error codes %3, %4

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

The drive processor signalled an internal system error to the NCK; the two error codes identify where and why. A classic case is insufficient computation time in the monitored cycle - notably with SINUMERIK Safety Integrated active (error no. 03, info 40: monitoring cycle too small), which trips STOP B/A responses on FDD/MSD.

Likely causes

  • drive cycle time too small for enabled functions (esp. Safety Integrated)
  • internal drive software fault / corrupted boot file
  • drive hardware fault in the closed-loop control module

Triage note: Look up codes %3/%4 in chapter 'Error Codes of Alarm 300500' of the Diagnostics Guide; remedy is usually POWER ON, larger cycle times, or reloading drive software - replacement is rare.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 300500 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog