Siemens alarm 300501: Axis %1 drive %2 maximum current monitoring
SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U
What it means
Drive current exceeded the hardware trip level; instantaneous overcurrent detected in the power section.
Likely causes
- motor cable short circuit or ground fault
- motor winding fault (burnt/insulation breakdown)
- IGBT failure in 611D power module
- incorrect motor data / power section code parameterization
Triage note: Always megger motor and cable before refitting a replaced module - repeated resets into an overcurrent can destroy a marginal power module.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
6SN1123-…
SIMODRIVE 611D power module · Primary suspect
- Request a quote →
1FT6/1FT7/1PH series motor (per axis)
feed/spindle motor (after megger test fails) · Common cause
- Request a quote →
6FX5002-…
motor power cable · Common cause