SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Drive current exceeded the hardware trip level; instantaneous overcurrent detected in the power section.

Likely causes

  • motor cable short circuit or ground fault
  • motor winding fault (burnt/insulation breakdown)
  • IGBT failure in 611D power module
  • incorrect motor data / power section code parameterization

Triage note: Always megger motor and cable before refitting a replaced module - repeated resets into an overcurrent can destroy a marginal power module.