RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 300502

Siemens alarm 300502: Axis %1 drive %2 maximum current monitoring of phase current R (measuring circuit error phase R)

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Overcurrent/current-measurement fault detected on phase R of the affected drive.

Likely causes

  • phase-to-phase or phase-to-ground short in motor cable
  • motor winding fault on the affected phase
  • failed current sense/IGBT leg on power module
  • loose motor terminal connection

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 300502 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog