Siemens alarm 300503: Axis %1 drive %2 maximum current monitoring of phase current S (measuring circuit error phase S)

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Overcurrent/current-measurement fault detected on phase S of the affected drive.

Likely causes

  • short in motor cable (phase S leg)
  • motor winding fault
  • power-module current sensing/IGBT failure
  • coolant ingress into motor connector

Triage note: Flood-coolant machines: inspect motor power connectors for ingress before condemning the module.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 300503 with your machine details — typical RFQ turnaround is 24–48h.