RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 300509

Siemens alarm 300509: Axis %1 drive %2 converter frequency exceeded

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Speed times number of pole pairs exceeded the maximum converter frequency of the power section (fmax formula uses MD 1400/1146/1147 and pole data). Either the axis genuinely ran too fast, or the speed actual value is being mis-counted because encoder lines or motor data are wrong.

Likely causes

  • wrong encoder line count in MD 1005 vs fitted encoder
  • encoder supply short-circuit/ground fault corrupting speed actual value
  • motor data wrong (pole pairs MD 1112, rated frequency MD 1134, speeds MD 1400/1146/1147)
  • mechanical overspeed (e.g. falling vertical axis, spindle run-on)

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 300509 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog