Siemens alarm 300513: Axis %1, drive %2 ground fault detected
SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U
What it means
Firmware ground-fault detection measured phase currents beyond threshold MD 1167 $MD_CURRENT_GROUND_IDENT, or shaft movement beyond MD 1168 during the test. This means leakage to protective earth somewhere in the motor circuit; detailed diagnostics land in MD 1169 $MD_DIAG_MOTORIDENT.
Likely causes
- ground fault in motor winding (moisture, insulation breakdown)
- damaged/chafed motor power cable or connector
- coolant ingress in motor connector
- genuinely asymmetric current measurement (false trip) - verify with MD 1169 detail
Triage note: Megger the motor and cable separately to split motor vs cable; read MD 1169 before parts-swapping.