RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 300513

Siemens alarm 300513: Axis %1, drive %2 ground fault detected

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Firmware ground-fault detection measured phase currents beyond threshold MD 1167 $MD_CURRENT_GROUND_IDENT, or shaft movement beyond MD 1168 during the test. This means leakage to protective earth somewhere in the motor circuit; detailed diagnostics land in MD 1169 $MD_DIAG_MOTORIDENT.

Likely causes

  • ground fault in motor winding (moisture, insulation breakdown)
  • damaged/chafed motor power cable or connector
  • coolant ingress in motor connector
  • genuinely asymmetric current measurement (false trip) - verify with MD 1169 detail

Triage note: Megger the motor and cable separately to split motor vs cable; read MD 1169 before parts-swapping.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 300513 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog