Siemens alarm 300515: Axis %1 drive %2 heat sink temperature alarm
SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U
What it means
Heatsink temperature of the 611D power unit exceeded the warning/alarm threshold.
Likely causes
- cabinet cooling fan failed or filter blocked
- heatsink fouled with dust/oil mist
- ambient temperature too high
- continuous overload beyond module rating
- failed internal temperature sensor on the module
Triage note: Clean filters/heatsink and verify load duty cycle before replacing the power module.