Siemens alarm 300610: Axis %1 drive %2 rotor position identification failed
SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U
What it means
Rotor position could not be determined from measurement signals (current-based rotor position identification failed).
Likely causes
- phase missing in motor-converter connection
- weak DC link (loose DC-link screws / missing bus voltage)
- Uce monitoring latched (reset by power cycle)
- defective 611D power section
- defective control module
Triage note: Official remedy ladder ends with: 'Replace the 611D power section' then 'Replace the control module'.