Siemens alarm 300610: Axis %1 drive %2 rotor position identification failed

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Rotor position could not be determined from measurement signals (current-based rotor position identification failed).

Likely causes

  • phase missing in motor-converter connection
  • weak DC link (loose DC-link screws / missing bus voltage)
  • Uce monitoring latched (reset by power cycle)
  • defective 611D power section
  • defective control module

Triage note: Official remedy ladder ends with: 'Replace the 611D power section' then 'Replace the control module'.