Siemens alarm 300613: Axis %1 drive %2 maximum permissible motor temperature exceeded

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Either the KTY84 sensor read through the motor encoder cable exceeded shutdown limit MD 1607, or the electrothermal motor model reached 100% utilization (MD 1266). This is the final overtemperature trip - the pre-warning stage (and 300614 time monitor) normally precedes it.

Likely causes

  • sustained motor overload (duty cycle, cutting parameters, counterbalance failure)
  • blocked/failed motor fan, clogged cooling ribs
  • temperature sensor or encoder cable fault giving false reading
  • winding fault raising current draw
  • torque/power limits (MD 1230/1235) set too high for the motor size

Triage note: After the trip, let the motor cool and compare sensor resistance against the KTY84 curve to separate real heat from sensor drift.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 300613 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog