Siemens alarm 300614: Axis %1 drive %2 time monitoring of motor temperature

SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U

What it means

Motor temperature measured via KTY84 sensor (fed through the motor encoder cable) exceeded MD1602 warn limit longer than permitted by MD1603; drive brakes regeneratively and inhibits pulses.

Likely causes

  • genuine motor overload / aggressive acceleration
  • blocked or failed motor fan
  • winding fault in motor
  • KTY84 temperature sensor fault or broken conductor in motor encoder cable
  • defective 611D control module evaluating the sensor
  • incorrect motor data (MD1102 motor code)

Triage note: Compare realistic temperature reading vs r0035-equivalent drive value; unrealistic readings indicate sensor/circuit, not thermal overload.