Siemens alarm 300614: Axis %1 drive %2 time monitoring of motor temperature
SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D) · SIMODRIVE 611D/611U
What it means
Motor temperature measured via KTY84 sensor (fed through the motor encoder cable) exceeded MD1602 warn limit longer than permitted by MD1603; drive brakes regeneratively and inhibits pulses.
Likely causes
- genuine motor overload / aggressive acceleration
- blocked or failed motor fan
- winding fault in motor
- KTY84 temperature sensor fault or broken conductor in motor encoder cable
- defective 611D control module evaluating the sensor
- incorrect motor data (MD1102 motor code)
Triage note: Compare realistic temperature reading vs r0035-equivalent drive value; unrealistic readings indicate sensor/circuit, not thermal overload.